What is the difference between L5 and L6?

What is the difference between L5 and L6?

NEMA L5 connectors are a series of locking connectors with a maximum specified voltage of 125V. NEMA L6 connectors are a series of locking connectors used with circuits with a maximum specified voltage of 250V.

What is PDU in rack?

In layman’s terms, a rack Power Distribution Unit (PDU) is a device that can be fitted with multiple outlets to effectively control and distribute electricity. The two main types of rack PDUs can be classified as either non-intelligent PDUs or intelligent PDUs.

Is a PDU the same as a UPS?

PDUs evenly distribute the amperage among the outlets, while the UPS will filter the power and provide surge protection. PDUs use and distribute the available amperage more efficiently, allowing your equipment to receive the best available power to maintain operation.

What is L6 30P?

Description: 30 AMPERE-250 VOLT (NEMA L6-30P) LOCKING PLUG, SPECIFICATION GRADE, IMPACT RESISTANT NYLON BODY, CABLE DUST / MOISTURE SHIELD (IP20), 2 POLE-3 WIRE GROUNDING (2P+E). * Power cords, plugs, connectors, outlets, inlets, receptacles, adapters are listed below in related products.

What does L5 20P mean?

A 5-20P is a standard straight prong plug or receptacle. If there is a L in the plug or receptacle description such as L5-20P this tells you that it is a Locking style outlet. Locking means the once the plug is inserted into the receptacle it is twisted to lock it into place. TWIST AND LOCK L5-20P STRAIGHT BLADE 5-20P.

Are L5 30R and L5 30P the same?

A pure L5-30R would be a receptacle that you would mount into an outlet box versus the connector which is pictured. A L5-30P (“P” for plug) would be the female plug that would fit into either.

What is the purpose of PDU?

A power distribution unit is a device for controlling electrical power in a data center. The most basic PDU is a large power strip without surge protection. It is designed to provide standard electrical outlets for data center equipment and has no monitoring or remote access capabilities.

What is a PDU type?

In telecommunications, a protocol data unit (PDU) is a single unit of information transmitted among peer entities of a computer network. In the layered architectures of communication protocol stacks, each layer implements protocols tailored to the specific type or mode of data exchange.

Can a PDU be plugged into a UPS?

The PDU plugs into a high-amperage outlet on the UPS system. The PDU spreads the high-amperage input among multiple low-amperage outlets, allowing the UPS system to power multiple devices from a single outlet.

What is the difference between L6 20 and L6-30?

Considering that the L6-20 is 20Amp and L6-30 is 30Amp then the max that the L6-20 can pull is 20A thru a 30A circuit. Thus the wiring is all rated fine to handle the load and it would be fine.

How do you wire a 30 inch L6 plug?

Hold the NEMA L6-30R receptacle and view the terminal screws behind it. Wrap the red wire clockwise around the brass terminal screw; tighten the connection with a screwdriver. Wrap the black wire clockwise around the brass terminal screw; tighten the connection.

What is the difference between L6 20 and L6 30?

What kind of power does a rack PDU use?

Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements.

Where to mount a vertical PDU in a rack?

Vertical Basic PDUs A variety of sizes meet the needs of many environments Mounts vertically on either side in the rear of the rack using industry standard button and keyhole mounting. Standard mounting faces the outlet towards the rear of the rack. This configuration fully prevents interference in the maintenance zone between rear RETMA rails.

How many outlets does a pdu1230 have?

Perfectly suited for high-density IT environments, the PDU1230 features 20 total outlets—12 rear C13, four front C13 and four front C19. The NEMA L6-30P input plug with long 15-ft. (4.57 m) cord connects to your facility’s compatible AC power source, generator or protected UPS to distribute power to connected equipment.

Why do we need APC basic rack PDUs?

APC Basic Rack PDUs provide reliable rack power distribution via a single input with multiple output receptacles and distributes power from low amperage single phase circuits to higher-power 3-phase solutions. Brochures User Guides Diagrams Rack PDU Selector FAQ