Popular tips

What is E6010 welding?

What is E6010 welding?

DESCRIPTION: Pinnacle Alloys E6010 is a quick-starting, cellulosic mild steel electrode with outstanding arc stability, penetration, and wash-in. It is ideal for welding in all positions and produces an X-ray quality weld with light slag that’s easy to remove.

What amp do I need for 6010?

For example, a 1/8-inch 6010 rod runs well from 75 to 125 amps, while a 5/32-inch 7018 rod welds at currents up to 220 amps. The side of the electrode box usually indicates operating ranges.

What is the difference between E6010 and E6013?

E6010 electrodes can only be used with direct current (DC) power sources. E6013 electrodes produce a soft arc with minimal spatter, offer moderate penetration and have an easily-removable slag. These electrodes should only be used to weld clean, new sheet metal.

What is the difference between E6010 and e7018?

E6010 is used for deep penetration welding, while E 7018 is used for welding metal that tends to crack, producing quality welds with excellent toughness and high ductility. E 6010 is used for welding the joint root-pass for proper penetration, and E 7018 is used for the hot-pass, fill-up, and cap beads.

What does 7018 mean in welding?

The 7018 Welding Rod The “E” in E7018 electrode indicates a tool used for an arc-welding process. The 70 means it makes welds that are very strong (70,000 psi). The 18 means two things: The “1” means the electrode can be used in any position, and the “18” means low hydrogen and usually DC current.

What does the 60 stand for in E6010?

The “E” indicates an arc welding electrode. The first two digits of a 4-digit number and the first three digits of a 5-digit number stand for tensile strength. For example, E6010 means 60,000 pounds per square inch (PSI) tensile strength and E10018 means 100,000 psi tensile strength.

Why is 6010 so hard?

These rods do not contain potassium in their flux covering as E6011. Potassium helps to stabilize the arc. Furthermore, for most welding requiring E6010 rods, you use whip and pause techniques that add extra stress to the welder. As a result, E6010 rods create an arc that is very hard to stabilize.

What does the 3 stand for in E6013?

rutile potassium based flux coating
In this case the “3” in E6013 tells that it has a rutile potassium based flux coating. The penetration of the electrode is light and it can be used with AC and DC currents.

What does the 1 in E7018 stand for?

The “E” in E7018 electrode indicates a tool used for an arc-welding process. The 70 means it makes welds that are very strong (70,000 psi). The 18 means two things: The “1” means the electrode can be used in any position, and the “18” means low hydrogen and usually DC current.

What’s the difference between E6010 and E6011 welding rods?

The E6010 and E6011 are kindred rods, and they are like cousins. The E6010 offers similar characteristics of the weld with that of 6011. Like the 6011, it provides deep penetrating arc and has the ability to weld even over paint and rust without a hitch. Compared to 6010, however, it offers less penetration but provides greater arc stability.

Which is the numbering system for welding procedure specifications?

This numbering system will be used on all Welding Procedure Specifications revised or developed in the future. The following describes the new numbering system: 1) SMAW using F-3 Electrodes (E6010, E7010-A1, E6011, etc.) 2) SMAW using other than F-3 Electrodes (E7018, E308-16, etc.)

What do the numbers mean on a 6010 welding rod?

Of course, the “E” stands for “electrode” while the first two numbers, like the “ 60 ” in 6010, means 60,000 pounds tensile strength per square inch. The tensile strength refers to the ability of the weld to resist being pulled apart. The third number “ 1 ” signifies it can be run in all four positions (horizontal, vertical, flat, and overhead).

What is the welding procedure for shielded metal arc?

2.0 WELDING PROCEDURE 2.1The Welding shall be done manually using Shielded Metal Arc Welding, SMAW process. 2.2Joints shall be made following the procedural stipulations indicated in CSA Standard W59-13 and may consist of single and multi passes in accordance with the approved Welding Procedure Data Sheet to which this specification refers.