What is Part B of the building regulations?
What is Part B of the building regulations?
Part B of the building regulations in England covers fire safety matters within and around buildings. The approved documents to Part B are in two volumes. The most recent editions were published in January 2013 and came into effect in April 2013.
What are the changes to Approved Document B?
Any flats greater than 11m storey height, guidance now requires sprinklers throughout the building. Corridors and common areas in the same building do not need to contain sprinklers providing they are fire sterile. This is set out in Paragraph 7.4 in Approved Document B.
Does Approved Document B apply to existing buildings?
The Approved Document can be downloaded below, with Volume 1 covering dwellings, including blocks of flats and Volume 2 covering buildings all other types of building covered by the building regulations. …
What is Part C of the building regulations?
Building Regulations – Part C Site Preparation and Resistance to Contaminants and Moisture. Section C1 of the Building Regulations is concerned with the health and safety of the building’s users in particular regard to the effects of pollution and contaminants which may be present on the site.
Where should fire escape access be installed?
Upper floor windows: On upper floors up to 4.5 meters from ground level, all habitable rooms (not kitchens or bathrooms) must be fitted with fire escape windows, unless the room has direct access to a protected stairway.
What is a protected stairway?
Protected stairways include exit routes as directed by OSHA that provide safe passages for employees to make their way out of a building in the event of a fire.
What is BB100?
BB100 is technical guidance primarily intended for those designing schools, in particular, technical specialists such as designers, contractors, building control officers (or equivalent) and fire safety officers.
What is the maximum travel distance to a fire exit?
The travel distance should be measured from the farthest point in a room to the door to a protected stairway or, if there is no protected stairway, to the final exit from the building. If there is only one escape route, the travel distance should not normally be more than 18 metres.
What is another name for Medicare Part C?
Medicare Advantage Plan
A Medicare Advantage Plan (like an HMO or PPO) is another Medicare health plan choice you may have as part of Medicare. Medicare Advantage Plans, sometimes called “Part C” or “MA Plans,” are offered by private companies approved by Medicare.
What is the minimum intermittent extract fan ventilation rate in a kitchen?
The Building Regulations (Document F) require the following intermittent ventilation rates in new dwellings. Alternatively ventilate continuously at 0.3l/s/m2: Kitchen areas: an extract rate of no less than 216m3/h 60 l/sec. For calculation purposes we recommend a minimum air change rate of 15 per hour.
What are the requirements for emergency exits?
Normally, a workplace must have at least two exit routes to permit prompt evacuation of employees and other building occupants during an emergency. More than two exits are required, however, if the number of employees, size of the building, or arrangement of the workplace will not allow employees to evacuate safely.
Do I need fire doors in a 3 storey house?
Building regulations stipulate that fire doors are required in the following key areas for domestic properties: New build or renovated domestic properties which have 3 or more storeys (including loft conversions) must have fire doors to every habitable room off the stairwell.
What do you need to know about Building Regulations 2010?
It provides guidance in relation to Part M of the Second Schedule to the Regulations as amended by the Building Regulations (Part M Amendment) Regulations 2010 (S.I. No. 513 of 2010). The document should be read in conjunction with the Building Regulations 1997 – 2010 and other documents published under these Regulations.
What are the building regulations for part m?
Building Regulations (Part M Amendment) Regulations 2010 (S.I. No. 513 of 2010), extends the definition of material alteration to include Part M. As a result, the Building Regulations apply to any alterations subject to the requirements of Part A, B or M.
When does the new building regulations come into effect?
This volume of this approved document supports requirements B1 to B5 of Schedule 1 to the Building Regulations 2010 as well as regulations 6 (3), 7 (2) and 38. It takes effect on 30 August 2019 for use in England.
What does it mean to not comply with building regulations?
(b) in a building or controlled service or fitting which before the work commenced did not comply with a relevant requirement, being more unsatisfactory in relation to such a requirement. Part M (access to and use of buildings). Use this menu to access essential accompanying documents and information for this legislation item.